Home > Knowledge > Content
Technical reference for laser distance meter X-20 X-30 X-40 X-50
- Oct 15, 2018 -

600 338 X20.jpg

1.      Tips code and solution

 

Information

reason

solution

b.L

The battery level is too low

Replace with a new battery

t.L

The temperature is too low

Raise the meter temperature

t.h

The temperature is too high

Lower the meter temperature

d.H

Overflowing of data

Re-measurement

S.L

The signal is too weak

Measure the target potion with strong reflective   ability or use the sighting target.

S.H

The signal is too strong

Measure the target potion with weak reflective ability   or use the sighting target.

H.F

Wrong hardware

Restart   the meter. If many times of startup & shutdown can’t solve the problem, please contact with the local   dealer.

During the use of the instrument, the instrument may appear the prompts as followed:


2.      Technical reference

Specifications   and models

X-20 X-30 X-40  X-50   

Product   dimensions:

115*39*23mm

Measurement accuracy

+/- 2 mm*

Unit

m/in/ft

Measurement   range (no reflector)

0.03-40 m          0.03-50 m

Measurement   time

0.1-3 s

Laser   class

II

Laser   wave length

635 nm

Laser   output power

<1 mw

Dust   proof and water proof

IP54

Turn   off the laser light automatically

60 s

Shutdown   automatically

480 s

Illumination

white LED

Measuring   standard switch

100000 times

Battery   indicator

Signal   strength indicator

Continuous   measurement(max/min)

Volume/area/ Pythagorean measurement function

Laying   off

Battery   lives:

AAA alkaline battery   (2*1.5), 5000 times

Weight

80g

Working   temperature range

-10 - 40

Storage   temperature range

-25   - 60


Related Products